Application Procedure
General-The substrate must be clean, dry, structurally sound and free of efflorescence, oil, grease, form release agents and curing compounds. Painted surfaces are not acceptable and the paint must be removed.
Job Conditions - Air and substrate temperature for application of the Self-Adhesive Mesh must be 40°F (5°C) or higher and must remain 40°F (5°C) or higher for a minimum of 24 hours.
Temporary Protection - Must be provided at all times until the wall system, including flashings, caps, and sealants, is completed to provide protection from climatic conditions and other potential damage.
Installation - Apply Self-Adhesive Mesh according to Master Wall Specifications. In general, Self-Adhesive Mesh is centered on the approved sheathing joints, corners, etc. prior to the application of WeatherStop or other approved Master Wall base coat or weather barrier. Lap Self-Adhesive Mesh a minimum of 2-1/2 (63.5 mm).
Limitations
Self-Adhesive Mesh is not intended for use as the exterior or primary reinforcement of any Master Wall Systems. For decorative shapes, a full layer of Standard Mesh should be used under the shapes when using Master Wall EIF Systems.