Ready Mix:  Add Water
Master Wall Ready OCS is a fibered type Portland cement-based bagged stucco with exceptional workability, open working time, water retention, early strength, shrinkage resistance and long-term durability. OCS is typically applied thinner than traditional stucco and is mixed at time of use with water.
Coverage
22 square feet  (2.0 square meters) - at 3/8" (9.5 mm) thickness
20 square feet  (1.8 square meters) - at 1/2" (12.7 mm) thickness
11 square feet  (1.0 square meters) - at 3/4" (19 mm) thickness

Coverages are estimated and vary

Weight:  80lbs (29.5kg)

Working Time:  About 1.5 hours under normal room temperature and humidity.

Drying Time:  24 hours under normal room temperature and humidity.

Application/Storage Temperatures:  40F (5C) to 110F (43C)

Shelf Life:  1 year under normal conditions.


Approved Substrates
(2.5#/sy self-furring metal lath)
Exterior gypsum sheathing (ASTM C79)
Dens Glass Gold®
GlasRoc®
FiberBond®
Durock®
PermaBase®
OSB/Plywood
(Direct Applications)
Concrete
Brick
Masonry
Others approved in writing
Application Procedure

Job Conditions - Air and substrate temperature for application of Ready OCS  must be 40°F (5°C) or higher and must remain 40°F (5°C) or higher for a minimum of 24 hours.  Provide temporary protection to  protect the wall system from damage until permanent flashings, caps and sealants are installed. Store materials in a dry place, within prescribed temperature  limits and out of direct sunlight.  Working and drying times are based upon normal room temperature conditions and will vary with temperature and humidity.

Preparation - The substrate must be approved by Master Wall Inc., clean, dry, structurally sound and free of efflorescence, oil, grease, form release agents and curing compounds or anything that would affect bond.  Painted surfaces are not acceptable and must be removed or metal lath applied.  All sheathed applications must receive a minimum of 2-layers code-approved asphalt felt or equivalent.

Prepare smooth or non-absorbent solid substrates by one of the following methods or a combination;    Sandblasting, chipping or acid etching, A dash-bond coat applied forcefully, bonding compounds such as Master Wall Stucco Ad Liquid or Primer 57, Furred or self-furring metal plaster bases as per ASTM C1063.

Mixing - Each bag of Ready OCS is mixed  clean, potable water. Using a clean mixer, first add 1/2 to 2/3 the water required, 1 bag Ready OCS, then the rest of the water to achieve the desired workability.  Mix materials for 3 to 5 minutes after all materials are in the mixer.  Total water content can vary between 1 to 1.5 gallons (3.8-5.7L).  Stucco Ad-Liquid may also be used instead of an equal amount of water..  See system data sheet for specific  levels required for increased warranties.

Tempering-The mixed stucco can be re-tempered one time within 1 hour.  Material older than 1-1/2 hours should be discarded.

Application
Apply OCS by hand or machine to a minimum nominal thickness of 3/8  (9.5 mm) for masonry, concrete and stucco applications.  Measure stucco coat thickness from the back of the metal plaster base not including ribs and dimples or from the face of solid substrates exclusive of  texture variations.  Where plaster abuts dissimilar materials, provide for separation.  To avoid cold joints the application should stop at corner angles, rustications, openings and control joints.

On metal plaster bases, apply Ready OCS with sufficient material and pressure to totally embed the metal base.  A second pass may be required to obtain the minimum thickness of 3/8  (9.5 mm), 1/2  (12.7 mm) suggested for better lath coverage.  Rod or straight edge the surface to provide an even base for the Superior Finish.

On solid plaster bases, dampen high-suction bases with clean water or Stucco Ad-Liquid prior to the application of Ready OCS.  Rod or straight edge the surface to provide an even base for the Superior Finish.

Curing-Moist cure using fogging, plastic films or other method acceptable  to the  design professional for 48-72 hours.  Mixes with Stucco Ad-Liquid do not need moist curing.  Allow to fully cure until clean, dry and hard before finishing-typically 7-14 days.  See Master Wall Technical  Bulletins and data sheets for additional curing, drying and application recommendations.

Clean Up-Tools and equipment can be cleaned with soapy water while the Ready OCS mixture is still wet.
Information contained in this product data sheet conforms to the standard detail recommendations and specifications for the installation of Master Wall Inc. products and is presented in good faith.  Master Wall Inc. assumes no liability, expressed or implied as to the architecture, engineering, or workmanship of any project.  This information may be concurrent with, or superseded by other applicable documents, such as specifications and details.  Contact Master Wall Inc. for the most current product information.

Copyright 2008 Master Wall Inc.
Home    About Us    Products    Colors & Textures    Commercial Systems    Residential Systems    Technical    Distributors  Training    Contacts    News & Events    Technical Bulletins    Reading Room    Distributors Only    Vintique
Copyright 2009 Master Wall Inc.
Aggre-flex EIFS  Aggre-flex Drainage EIFS  I  Rollershield Drainage EIFS  I  One Coat Stucco (OCS)  I  Insulated Concrete Form (ICF) Coatings  I  Cemplaster (Portland Cement) Stucco  I  Stucco Cement Board Coatings  I  Aggre-flex Commercial Drainage EIFS  I  Uninsulated Finish System  I  QRW1 Drainage EIFS  I  Superior Finishes over Stucco
Aggre-flex EIFS  Aggre-flex Drainage EIFS  I  Rollershield Drainage EIFS  I  One Coat Stucco (OCS)  I  Insulated Concrete Form (ICF) Coatings  I  Cemplaster (Portland Cement) Stucco  I  Stucco Cement Board Coatings  I  Aggre-flex Commercial Drainage EIFS  I  Uninsulated Finish System  I  QRW1 Drainage EIFS  I  Superior Finishes over Stucco Rollershield LAB